Appearance
Indoor fan relay · CAUSE ARTICLE

Open, resistive or welded relay contacts

Contacts fail to pass the required power, or stay closed after the command is removed.

What happens

Contacts fail to pass the required power, or stay closed after the command is removed.

Typical symptoms

Relay clicks but blower stays off; alternatively, the blower runs continuously.

Checks that distinguish this cause

Compare command state with actual output, allowing for documented fan-off delays. Evaluate isolated contacts or authorized loaded voltage measurements as appropriate.

What can look similar

A thermostat fan-on setting or board purge sequence may intentionally run the blower.

Repair direction

Replace the proven faulty approved relay or board and investigate abnormal motor loading.

Verify the repair

Verify both commanded operation and proper stop timing.

Equipment-specific limits

Some control boards contain an integrated relay; ECM controls may not use this conventional arrangement.

Practice this diagnosis

These simulated calls exercise this component or repair family. The article describes a broader diagnostic process; a call may represent a different cause within that family.

References and applicability

Original HVACSim explanations with manufacturer and instrument-maker references for further reading. These resources support the subject; their model-specific examples are not specifications for every system.

Editorial review: 2026-09-29. Verify the current manual for the installed model.